EMERSON EWL20S5 SEREVCIE MODE AND POWER SUPPLY CIRCUIT

SEREVCIE MODE AND POWER SUPPLY CIRCUIT

Category : Lcd Television Repair  

SERVICE MODE

1. Use the service remote control unit.
2. Turn the power on. (Use main power on the TV unit.)
3. Press [SLEEP] button on the service remote control unit. Version of micro computer will be displayed on the LCD or display. (Ex: 0008GP- 0.08)

Initial Setting

General: Enter the Service mode

Set the each initial data as shown on table  below

Initial Data
Item
Button
(on the service
remote control)
Data
Value
BRT



[MENU]à[1]
128
CNT
124
CLR-R
64
CLR-B
64
TNT
128
V-TNT
128
SHR
112
S-BRT


[MENU]à [2]
128
S-CNT
128
S-CLR-R
64
S-CLR-B
64
S-TNT
128
S-SHR
112
C-BRT


[MENU]à[3]
128
C-CNT
128
C-CLR-R
64
C-CLR-B
64
C-TNT
128
C-SHR
112
D2-BRT


[MENU]à[5]
133
D2-CNT
140
D2-CLR-R
74
D2-CLR-B
74
D2-TNT
128
D2-SHR
112
D3-BRT


[MENU]à[6]
126
D3-CNT
138
D3-CLR-R
64
D3-CLR-B
64
D3-TNT
128
D3-SHR
112
DR(C/D1)
[VOL V ]à [4]
176
C-DR(C/D2)
157
DB(C/D1)
[VOL V ]à[6]
175
C-DB(C/D2)
152
Flicker Adjustment

1. Enter the Service mode.
2. Press [2] button on the remote  control unit.
3. If Flicker Adjustment is not fit,.
4. Press [CH UP/ DOWN] buttons on the remote control unit so that flash stops.

White Balance Adjustment

Purpose: To mix red, green and blue beams correctly for pure white.
Symptom of Misadjustment: White becomes bluish or reddish
Note: Use service remote control unit
1. Operate the unit for more than 20 minutes.
2. Input the White Purity (APL 80% or APL 20%).
3. Set the color analyzer to the CHROMA mode and bring the optical receptor to the center on the LCD-Panel surface after zero point calibration as shown above.
Note: The optical receptor must be set perpendicularly to the LCD Panel surface.
4. [RF/VIDEO1]
Enter the Service mode. Press “VOL DOWN” button on the remote control unit and select “C/D-1” mode.
[VIDEO2]
Enter the Service mode. Press “VOL DOWM” button on the remote control unit and select “C/D-2” mode.
5. [RF/VIDEO1]
When “x” value and “y” value are not within specification, adjust “DB (C/D1)” or “DR (C/D1)”. Refer to “1. Initial Setting.”
Note: “DB(C/D1)” or “DR(C/D1)” must be adjusted within ±0.01.
[VIDEO2]
When “x” value and “y” value are not within specification, adjust “DB(C/D2)” or “DR(C/D2)”. Refer to “1. Initial Setting.”
Note: “DB(C/D2)” or “DR(C/D2)” must be adjusted within ±0.01.
6. Turn the power off and on again. (Main power button on the TV unit.)

How to initialize the LCD television:

1. Turn the power on. (Use main power on the TV unit.)
2. To enter the service mode, press [SLEEP] button on the service remote control unit.
- To cancel the service mode, press [POWER] button on the remote control.
3. To initialize the LCD television, press [DISPLAY] button on the remote control unit.
4. Confirm "FF" indication on the upper right of the screen.

POWER SUPPLY CIRCUIT 
Power supply board 
CLICK ON THE IMAGE TO ZOOM IN

INVERTER CIRCUIT 
CLICK ON THE IMAGE TO ZOOM IN